  • Conductor
    Material CCA(Copper content 22%–31%)
    Diameter 0.57 mm ± 0.01 mm
    American Wire Gauge 23AWG
    Insulation
    Material HDPE
    Min. Average Thickness 0.21 mm
    Diameter 1.02 mm ± 0.06 mm
    Color (4 Pairs) Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
    Separator
    Material PE
    Specification Translucent 4.5 × 0.4 mm
    Rip Cord
    Material Polyester
    Specification 500D
    Sheath
    Material PVC
    Min. Average Thickness 0.5 mm
    Diameter 6.5 mm ± 0.3 mm
    Color Orange
    Electrical
    Max. DC Resistance of a Single Conductor 11.5Ω/100 m
    Min. Insulation Resistance 5000MΩ·km
    Max. DC Resistance Unbalance 2% (pair intra), 4% (pairs inter)
    Dielectric Strength No breakdown with 1KV DC for 1 min
    Transmission
    Characteristic Impedance 100 ± 15Ω
    Near End Cross Talk ≥39.30 dB/100 m@250 MHz
    Max. Attenuation 34.8 dB/100 m@250 MHz
    Return Loss ≥17.3 dB/100 m@250 MHz
    Mechanical
    Tensile Strength Sheath≥13.5 MPa, insulation≥16 MPa
    Elongation at Break Sheath≥150%, insulation≥300%
    Installation Bending Radius >8 times of outer cable diameter
    Conductor Elongation at Break ≥10%
    Environmental
    Shrinkage of Insulation ≤5%
    Color Migration Resistance of Insulation No migration
    Sheath Tensile Strength and Elongation at Break after Aging ≥12.5 MPa, ≥100%
    Low Temperature Bending Test No cracking after the test
    Heat Shock Test No cracking after the test
    Operation Temperature –20°C to +60°C (–4°F to 140°F)
    Installation Temperature 0°C to +50°C (32°F to 122°F)
    Storage Temperature and Humidity –10°C to +40°C (14°F to 104°F), <60% (RH)
    Security
    Vertical Fire Propagation Test Comply with IEC 60332-1-2
    Packaging
    Length 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
    Packaging Dimensions 390.0 mm x 390.0 mm x 247.0 mm (15.37″x15.37″x9.73″) (L × W × H)
    Packaging Method 305.0 m (1000.66 ft) a carton, one protection carton with 2 cartons inside
    Net Weight ≥9.2 kg (20.28 lb)
    Gross Weight ≥10.2 kg(22.49 lb)
    Executive Standard
    Executive Standard Q/DXJ 067-2019
    Certification
    Certification CPR Eca